Small Tool Instruments andData ManagementTest Equipment andSeismometersDigital Scale and DRO SystemsCoordinate Measuring MachinesSensor SystemsOptical
10Gage Head OverviewLaser Hologage Laser Hologage• 0.01µm resolution• Sine wave output• ø15mm plain stem• 1µm resolution• Square wave out put• ø9.5mm
11• 0.1µm resolution• Square wave output• ø8mm / ø15mm stemø8mm stemø15mm stemRange: 10mm / .4” Range: 25mm / 1”LGF seriesCompatible display unitCompa
12• 0.01mm resolution• Digimatic output• Absolute linear encoder• ø8mm / ø15mm stemø8mm stemø15mm stemø15mm stemRange: 10mm / .4” Range: 25mm / 1” Ran
13Display Unit OverviewSingle function typeSingle function typeMulti-function typeMulti-function type for multi-gage systemMulti-function typeEC-101DF
14GageHeadsAttachment thread for thrust stemM9.5X0.510.6 or longer (stroke)ø8-0.0090146.573.1ø12125.5Attachment thread for thrust stemM9.5X0.510.6 o
15GageHeadsM9.5×0.5M9.5×0.502ADB68202ADB681(screw top height)Dimensions with a thrust stem installed12(13.8)ø9.5-0.015 0414.59.5617.3ø812.3346.9(129.5
16GageHeadsSleeveø16.7ø6.234.0Sleeveø16.7ø6.234.06(screw top height)Dimensions with a thrust stem installedM9.5×0.5M9.5×0.5Clamp nut02ADB682Thrust ste
17GageHeadsFEATURES(screw top height)10.6 or longer(stroke)Connecting cable2mDimensions with a thrust stem installedM9.5×0.5Attachment thread for thru
18GageHeads37.3 17 5.9 65.925.9146.13517.4ø10.56.824.2378.620FEATURES*1: Excluding quantizing error of ±1 count.*2: IP level is the standard of protec
19GageHeads378.620Connectingcable2m(screw top height)M14×0.5M18×1Thrust stemClamp nut02ADN37102ADB69221(24.2)ø18-0.018 05918.520.630.761.7ø15-0.015013
2Suitable for in-line useSuitable for close-pitched applicationsMeasurement principle The gage head processes internally detected signals and outputs
20GageHeads3082.720.4ø918ø9ø14ø9.50-0.009756.315.925.14.9 (thread)Clamp nutNo.200365LL=11.5 to 13.0Connecting cable (2m)(HIROSE)RM12BPE-6PH60.150.3113
21GageHeads20.4304710011315.434.9Connectingcable (2m)Dsub 15-pinø80-0.009ø918ø9ø8924.67520.43082.7Connecting cable (2m)(HIROSE)RM12BPE-6PH7.30-0.00920
22GageHeadsRM12BPG-6P (HIROSE)Connecting Cable 2m2-ø4.5, ø9 depth 5331720ø6495013429Stroke 102 or longer191.56-0.0130ø20736243.568342-ø4.5, ø9 depth 4
23GageHeadsOutput cable 2mDrive unit cable 2m2-ø4.5, 9 depth 5 RM12BPG-6P (HIROSE) HR10A-7P-6P (HIROSE) 1350-0.0130ø206191.5Stroke 102 or longer ø6429
24GageHeads45.4851462510 (Measuring range)1020ø15h618400-0.011Display UnitConnector for lifting cableSR5 carbide point144156.7148.213711.272(3.1)The M
25GageHeads 202 300 103.2 56 380.2 Measuring table ø100Measuring tableclamp screwContact pointDisplayOperating switch85 15017082.95ø3212.5 29 80 1
26GageHeadsDimensions Unit: mm7.32010.649.6537.213.543.567.480.77.6ø10.5ø54ø60.51628.5204m, ø5mm,Core wire AWG/24M2.5×0.45ø6.5ø8 0-0.009FEATURES• Empl
27Signal ID-CCalculation ID-CIndicator Display unit External deviceSignal Output TypeStandard TypeID-C ID-U ID-SCalculation TypePeak hold ID-CPeak Hol
28Differential square-waveDifferential square-wave with Origin Point MarkGageHeads123654Output Signal Specifications2) Recommended processing circuit f
29Differential square-waveTr (min.) 5µm / 1µm / 0.5µm (resolution)Phase APhase BData output timing: 1µm resolution LGB and 1µm / 0.5µm resolution
3ContentsLG Long Stroke Type 22LGM Motor-drive, Long Stroke Type 23Laser Hologage High-resolution Type 24Litematic Head and Litematic 25Signal I
30GageHeadsOutput Signal Specifications Recommended external I/FLGD sideVcc• CK,D ATA• REQ,ORIG R1R1TrCMOSinputR2VddC74HC14, etc. For Vcc
31GageHeadsFEATURESFor LGS: 903594 (mm), 903598 (inch) For 10mm LGD / LGF / LGK: 02ADE230Unit: mmUnit: mmUnit: mmFor 25mm LGD / LGF: 02ADE250 For 50mm
32GageHeadsNut mountingSplit-clampmounting(4.5)7.515306AA-A' section A-A' section ø4.5, ø7.5 depth 4.4 1615(9)A'M4x0.7ø8H7+0.0150+0.015
33Set order No.* 02ADB680 02ADN370Compatible gage 10mm LGD / LGF / LGK 25 / 50mm LGD / LGFPart No.Thrust stem 02ADB681 02ADN371Clamp Nut 02ADB682 02A
34SPECIFICATIONS SPECIFICATIONS• A signal cable from the head to the receiver circuitry can be extended.• Maximum number of connectable cables is limi
35504ø2412(stroke)43Return-speed adjustment knobSpindle-lift release for the Laser Hologage. A sudden drop of the spindle is prevented by the return-
36*Note: If the perpendicularity with the stem or parallelism with the reference surface is required when using Flat Points, it is necessary to use a
37Display UnitsSystem Connections and Comparison of Counter FunctionsDisplay unitEC Counter EG Counter EB Counter EH Counter EV CounterEC-101D EG-101P
38!##!""This software facilitates the loading of measurement data from the EH / EV counter or Litematic USB connection is possible wit
39Display UnitsFEATURESCOMSupply voltage: Max. 24VOutput current: Max. 10mAOutput saturation voltage: Max. 0.7VOutput* Protection diode rating 60V/1
4WorkingStandardMeasuringInstrumentTraceability oftemperature fieldMitutoyo MetrologyCalibration Center(JCSS AccreditedCal. Lab. No.0031)Temperature fix
40Display UnitsFEATURES 154.6 48 96 96 6.6 137 (11)91.444.4 154.6 48 96 96 6.6 137 (11)91.444.4 154.6 48 96 96 6.6 137 (11)91.444.4S
41COMSupply voltage: Max. 24VOutput current: Max. 10mAOutput saturation voltage: Max. 0.7VOutput* Protection diode rating 60V/100mA minimumRelay cir
42Display UnitsProgram ControlerTolerance judgment result outputSerial BCD outputAnalog outputSerial BCD outputAnalog outputDigimatic outputPersonal c
43Powerful tolerance judgment function1) Keeps up to seven 3-step/5-step tolerance limits in memory. It is possible to switch these tolerance limits
44Input / output specifications1) Suitable plug: 02ADB440 (with cover)2) Pin assignmentDisplay Units66n Pin No. Description I/O Function
45-IN¬¬¬SEC¬¬¬RESPRESENTS¬%"$¬-IN¬¬¬SEC0OWER¬SUPPLY(/,$./-)/¬OUTPUT-IN¬MS-AX¬MS-IN¬«S -IN¬«S03%4$!4!-AX¬«S-IN¬MS-
46Display UnitsFEATURES542-075z542-075-1542-071z542-071-1542-073z542-073-1542-074542-074-1542-072542-072-1SPECIFICATIONSOrder No.542-075z 542-071z 542
47Functions1. Zero-set Sets the displayed value to 0 at any position of the spindle.3-stagejudgement(GO/±NG)5-stagejudgement–NG GO1Li
48Display UnitsA/B_bit0 1 x 1001 x 107D1 D2 D3 D4 D8A/B_bit1 1 x 1002 x 107A/B_bit2 1 x 1004 x 107A/B_bit3D1 D2 D3 D4 D5 D6 D7 D8Bits 0-3 1 0 6 5 4 3
49Input / output specifications1) Suitable plug: 02ADB440 (with cover)2) Pin assignment3) I/O circuit1. Output circuit NOM, AL1 to AL5, BL1 to BL5 Tra
5National metrology instituteAccreditation body APLAC<MRA>EA<MRA>Accredited calibration laboratory UKASMitutoyo UK No.0332*2UKTAFMitutoyo
5067 (11)6.691.444.49648SPECIFICATIONSFEATURES• Display unit for the EV counter.• Using this display allows various settings for the EV counter to be
51Display UnitsFEATURES1446.54.5441366725516116161394464Tie blockMountingfixtureEV CounterDIN size (144 x 72mm) assembly-type unit for multi-gage syste
52Display UnitsCEL1GageselectorNORMAL mode High-speed mode Differential measurement mode Origin•Tolerance• Peakmeasurement Origin•Tolerance• Peakmeasu
53RS-232C specifications1) Compatible plug: D-sub 9-pin (female), inch thread specification2) Pin assignmentRS Link* functionIt is possible to connec
54Output functionsSelect either “Tolerance judgment result output”, “Segment output”, or “BCD output” depending on the application needs.Display Units
55+5V5KΩCOMOutput74HC14equivalent0.01µFTD62583 equivalentSupply voltage: Max. 24VOutput current: Max. 10mAOutput saturation voltage: Max. 0.7VCounterE
56Display UnitsOptional AccessoriesThe connectors listed below are compatible with the specific models of counter shown for measurement, data output, a
57D/A conversion unit LG-DA1: 542-003zFEATURES• This unit consists of the pulse control circuit, counting circuit, and D/A conversion circuit to outp
5858Quick Guide to Precision Measurement0.0000.0000.000MAXMINTIR (run-out) = Maximum - minimum1.234123.456+ –/Referencesurface3step(GO/±NG)5step–NG GO
59The offset registerLimit of spindle retractionInternal counter value (invisible)Offset register value (invisible)Display value (visible)Limit of spi
6ApplicationsMultipoint measurement of automobile doorsGage heads (LGS with EV counter) can be used to perform multi-point measurements for automobile
60The use of a thrust stem allows a gage head to be mounted securely and easily just by drilling a ø9.5mm hole (or ø18mm for ø15mm stems) in a plate a
61Provided with power supply terminal. Input power of 12 to 24VDC (1A or more).Insert a gage in the mounting hole (recommendation: ø9.5_H6) and fix i
Small Tool Instruments andData ManagementTest Equipment andSeismometersDigital Scale and DRO SystemsCoordinate Measuring MachinesSensor SystemsOptical
7Built-in sensor for machine toolsA gage head (LGM with EH counter) can be used to measure a workpiece which has been machined on a surface grinder.Ro
8Multipoint measurement of VTR chassisGage heads (LGF with EV counter) can be used to measure VTR components at several points.Measurement of hub runo
9Multipoint measurement of LCD panelGage heads (LGF with EH counter) can be used to measure distortion of LCD panels.Height measurement of cellA gage